Validated type 1 process indicator and sterilization label for. Sterrad velocity systems deliver bi results in just 30 minutes. System operation sterrad 100 s theory of operationsterrad 100 s theory o. Sterrad 100 sterilization system service guide advanced sterilization products 33 technology irvine, california 92618 1888sterrad ts028590002 rev d this guide contains information on servicing the sterrad 100 s sterilizer.
Log sheets document pertinent cycle information for sterilization, liquid chemical sterilization and high. Class 2 device recall sterrad 50 sterilization system. Its the only pdf viewer that can open and interact with all types of pdf content, including. Sterrad nx standard and advanced cycles with and without. The sterrad 100s system is a multipurpose sterilizer intended for use in the sterile processing departments and ors of hospitals and other medical facilities.
Advances in hydrogen peroxide gas plasma sterilization. Compatibility with the sterrad velocitytm biological indicator and reader system, which pro. Compatibility of olympus products with the sterrad 50 and. The sterrad 100s sterilizer can process many of the items you commonly sterilize as well as instruments that are sensitive to heat and moisture. This sterilizer offers an effective, safe, fast, economical. For information regarding sterrad 50 and 100s indications for use and sterilization efficacy, please contact asp. We have 2 asp sterrad nx manuals available for free pdf download. Advanced sterilization products asp your leaders in.
Sterrad technology asps sterrad 100s system is now better than ever with an improved design. Accessgudid sterrad 10705037014460 sterrad 100s sterilizer. With its tradition of reliability and efficiency, the sterrad 100s system offers performance you can count on for simplicity in instrument processing. Introduction overview the sterrad 50 sterilization system is a general purpose, low temperature sterilizer using the sterrad process to inactivate microorganisms on a broad range of medical devices and surgical instruments. Asp sterrad 100sover 18 years of proven sterrad technology, with its tradition of reliability and efficiency, the newlydesigned sterrad 100s system offers p. Read, understand, and follow the medical device mfrs instructions for their products. Asp sterrad 100s sterilizer featuring single button. Asp advanced sterilization products sterrad 100s plasma. An ebook reader can be a software application for use on a computer such as. Asp sterrad 100s community, manuals and specifications.
None of the equipment posted for sale on is owned by medwow, should you have any questions regarding a. Asp sterrad nx manuals manuals and user guides for asp sterrad nx. The sterrad 100nx system was designed to meet customer needs for a fast, versatile, and large sterilizer. Manufacturer specifications sterrad 100s, asp advanced sterilization products please note. Metal and nonmetal lumened instruments with inside. Sterrad 100nx standard, flex, express, and duo cycles with and without allclear technology sterrad nx standard and advanced cycles with and without allclear technology sterrad 100s the indications for use statement for the sterrad velocity biological indicator and reader is. Validated type 1 process indicator and sterilization label for vaporized hydrogen peroxide sterilization. And now, its connected to the adobe document cloud. Asp sterrad 100 service manual free ebook download as pdf file. The sterrad 100s sterilizer can sterilize instruments which have diffusionrestricted spaces, such as the hinged portion of forceps and scissors. Featuring touchscreen technology and a smart bi, it is also fully integrated with all the latest features of sterrad system sterilizers. Verify sterility in 15 or 30 minutes to result dependent on sterrad velocity reader software version t o release instruments to the or faster than before. By continuing to browse the site you are agreeing to our use of cookies.
At the basis of the sterrad 100s sterilizer is the germicidal property of hydrogen peroxide already known at the beginning of the 20th century 3. The sterrad 100nx system with allclear technology is a low temperature sterilizer that offers. If you are a sterrad nx sterilizer operator, you must read the. Sterrad velocity bi system terminal sterilization asp. Vpro 60 low temperature sterilization system steris. Sterrad 100s service manual service technicians forum. Johnson and johnson sterrad nx cassettes 5 cycle box of 5. At the completion of the sterilization process based on this technology, no toxic residues remain on the sterilized items. Asp sterrad 100nx autoclave sterilizer featuring a 24minute. Adobe acrobat reader dc software is the free global standard for reliably viewing, printing, and commenting on pdf documents. Advanced sterilization products inc franks hospital workshop. Sterrad velocity bipcd is the only system for frequent monitoring and periodic testing of sterrad sterilizers that meets aami standards. Trusted the sterrad systems brand has the most mdm ifu endorsements for low. And to create, protect, convert, and edit pdfs, try out acrobat pro.
View, sign, collaborate on, and annotate pdfs with our free adobe acrobat reader. The sterilizer has the same footprint as the sterrad 100s system but stands 4 inches taller. A disinfectant that is vah listed, epa registered or locally recognized is recommended. Means have been sought to circumvent these impracticalities. The sterrad nx sterilization system is a general purpose, low temperature sterilizer which uses the sterrad nx process to inactivate microorganisms on a broad range of medical devices and surgical instruments. Designed with three sterilization cycles, the vpro 60 sterilizer helps you rise above the curve wherever you reprocess your medical devices. Asp launches new duo cycle for sterrad 100nx system. Sterrad is a registered mark of advanced sterilization products. This sterilizer offers an effective, safe, fast, economical, easy to use, reliable, and flexible sterilization method. None of the equipment posted for sale on is owned by medwow, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page. Download reader try acrobat pro amplify your pdf skills with a click. Only with adobe acrobat reader you can view, sign, collect and track feedback, and share.
Validation of a lowtemperature, lowpressure, vaporized hydrog. Service technicians forum sterrad 100s service manual pasquale mazzone idem i am looking for service manual of asp sterrad 100s. Apr 28, 2015 this feature is not available right now. As a precaution, personnel should leave the room if mist is observed and avoid returning until the mist has cleared. We started the refurbishing process but we can,t find the printer. The sterrad sterilization system by advanced sterilization products asp exploits the synergism between peroxide and low temperature gas plasma an excited or ionized gas to rapidly destroy microorganisms figure 1.
Determining what can be sterilized in the sterrad nx sterilizer 26. Upgradeable technology as innovations come available. Introducing the vpro 60 sterilizer, the countertop sterilizer you have been looking for. The sterrad sterilization system by advanced sterilization products asp exploits the synergism between peroxide and low temperature gas plasma an excited or ionized gas to rapidly destroy. The system employs the proprietary sterrad technology, a hydrogen peroxide gas plasma process to achieve at least a 106 sterility assurance level in a 55. Vh2o2 biological indicator system sidebyside comparison. It offers an unparalleled breadth and depth of educational and training programs. In the sterrad 100s sterilizer, aqueous hydrogen peroxide is vaporized in a cylindrical chamber at low temperature and low pressure. Designed with three sterilization cycles, the vpro 60 sterilizer. The sterrad sterilization process is a combination of vapor hydrogen peroxide and plasma commonly referred to as gas plasma.
Attest for vaporized hydrogen peroxide biological indicator. The sterrad 100nx and sterrad nx systems never registered a value above 0. Sterrad systems sterilization guide for battery power line ii bpl ii liion battery 530. Plasma sterilizer a mains electricity acpowered device designed for total elimination andor inactivation of microorganisms from medical devices and related products using vapours or gases in plasma state. Sterrad nx syste by advanced sterilization medline. Learn more about asps sterrad velocity biological indicator system. None of the equipment posted for sale on is owned by medwow, should you have any. Envelopes, forms, record cards and labels to quickly document common sterilization, high level disinfection and cleaning processes. The sterrad 100 s sterilizer process has four distinct phases. The sterrad 100 s sterilizer has two separate peroxide injectionsplasma stages, rather than one, in the sterilization cycle. Plasma sterilizer a mains electricity acpowered device designed for total elimination. Sterrad 100s cassettes 5 cycles each 5 cassettes per box 101. The sterrad sterilization process is a combination of vapor hydrogen peroxide.
Networking capability with multiple instrument tracking systems and hospital servers. Metal and nonmetal lumened instruments with inside diameters of 6 mm 14 inch or larger and lengths of 310 mm 12 inches or shorter can be processed in the sterrad 100s sterilizer. This is a controlled proprietary and confidential document. View and download asp sterrad nx user manual online. The firm sent an urgent device correction letter dated 42308, notifying customers of a situation that may occur with all models of sterrad sterilization systems 100s, 50, 200, nx and 100nx. Advanced sterilization products asp announced today the availability of an expanded sterrad 100nx system with four cycle options, including the new duo cycle for sterilizing most flexible endoscopes and their associated cameras and light cords, including those from olympus.
975 812 176 924 1320 222 1324 256 256 158 833 129 1511 1391 1184 807 1116 602 472 1096 213 1360 293 25 510 710 707 937 295 984 53 506 380 1260 1471